Filter Minder® Graduated Pressure Indicator - Higher

 

Model No. EP56019
HVAC Indicator and Cabin Pressure Indicator

How Does It Work?

The graduated pressure indicator monitors exhaust backpressure and other mid-range pressure applications. The position indicator progressively fills the window as filter restriction increases, locking at the highest restriction. The filter should be changed when the position indicator reaches the red zone.

Mounting

  • Remote Mount Only

Unique Features

Can be configured to measure pressure vs. atmospher OR differential pressure.

Specifications

  • Pressure Indicator
  • Locking Type (Non-Locking Available)
  • Operating Temperature: -40 to +250°F (-40 to +121°C)
  • Accuracy: ±10% at red zone
  • Material: Polycarbonate housing
  • Standard Calibration: 3-6 psi at the red zone

Dimensions

  • Length: 99.5 mm
  • Diameter: 32.0 mm
 
 
 
 
 
Engineered Products Co. | 2940 Airport Blvd. Waterloo, IA 50704 | P: (319) 234-0231 | F: (319) 234-8922 | E: info@filterminder.com