Filter Minder® Heavy Duty Pressure Sensor

 

Model No.HVAC Indicator and Cabin Pressure Indicator 115202

How Does It Work?
The sensor monitors vacuum and/or pressure on filter systems or virtually anywhere vacuum or pressure needs to be monitored. It gives a progressive output from .5 to 4.5 volts full scale. It is an absolute sensor not vented to atmosphere and can measure vacuum and/or pressure from .5 to 300 psia (3.4 to 2068 kPa). Some applications include: fuel pressure, oil pressure, air pressure, water pressure, gaseous pressure and others. See specifications for standard mounting and connector availability. Special mounting and connectors available if annual volume warrants (contact Filter Minder).


Specifications

  • Measurement Type: Vacuum and Pressure (Absolute)
  • Working Pressure Range: 0.5 to 300psia (3.4-2068 kPa)
  • Media: Diesel Fuel, Biodiesel, Gasoline, Hydraulic Fluid, Air, etc.
  • Burst Pressure: 3X Operating Pressure
  • Proof Pressure: 2X Operating Pressure
  • Supply Voltage: 5 Vdc ± .25 Vdc
  • Supply Current: 10 mA MAX
  • Current Output: 2.0 mA
  • Output Impedance: 2.5 kΩ MIN
  • Accuracy: < ± 2.5% full scale from –40°C to +140°C
  • Output Voltage: 0.5 - 4.5 Vdc ; Ratiometric between 3.5 v and 6.5 v supply
  • Over-voltage Protection: 33 V for 5 minutes
  • Reverse Polarity Protection: 33 V for 5 minutes
  • Operating Temperature: -40°C to 140°C [-40°F to 284°F]
  • Extreme Temperature Short Term: -40°C to 150°C [-40°F to 302°F]
  • Life Cycle: >10 million Full Scale
  • Vibration Envelope: 10-2000 Hz at 10 g’s
  • Housing Material: PPS and Stainless Steel
  • Electrical Termination: 18 AWG GXL wire leads or Amp 16 or Deutsch DT04
  • Mounting Configuration: Various mounting configuration available
  • Response Time : ~ 1 ms Full Scale
    Turn on Time : ~ 1 ms

Dimensions


 

 
 
 
 
 
 