Engineered Products 2940 Airport Blvd.
Waterloo, IA 50703

319-234-0231 - Phone
319-234-8922 - Fax

www.filterminder.com
info@filterminder.com

 
Home Products Purchase Support Contact Us

 

Filter Minder® Air Filter Switch - Non-Locking

HVAC Indicator and Cabin Pressure Indicator
Model No.
196389
(Packard Metri-Pack 150 series)
196351
(Ampseal 16)


How Does It Work?

Continuously monitors air filter and tells when filter is restricted.  Triggers air filter warning light via the engine computer or directly to the warning light. Used for air filter monitoring on diesel, gas, and alternate fuel engines, as well as other applications where low vacuum/pressure monitoring is required.

Specifications

  • Operating Temperature: -40 to +250°F (-40 to +121°C)
  • Vacuum Ranges: minimum 3 " H20 (0.75kPa) ± 10% @ 23°C to 50 " H20 (12.4 kPa) maximum ±10% @ 23°C
  • Pressure Ranges: Lowest set point - 0.11 PSI (0.75 kPa) ±10% @ 23°C.  Highest set point - 2.0 PSI (14 kPa) ±10% @ 23°C
  • Chemical Resistance:  Resistant to exposure to all under hood fluids
  • Max Carrying Current: 5 amps
  • Open Current Voltage:  0-48 volts
  • Tested Vibration Envelope:  15-2000 Hz, 8g
  • Minimum g Load to Cause False Reading:  10+ g's
  • Material: Nylon
  • Mounting Port Connections: 3/8" straight thread o-ring, M-10x1 Metric or 1/8" NPT Pipe Thread
  • Mounting Attitude: Switch may be mounted in any orientation
  • Switch: Normally open or closed available
  • Max. Switching Current: 300ma (non-conductive load)
  • Max. Continuous Pressure to the Mounting Port: 20 PSI (138kPa)
  • New generation self-cleaning switch design
  • Heavy duty design for severe duty service
  • Molded-in sealed connector receptacle
  • External shield, barrier filter, and labryinth protects switch

Dimensions

  • Length: 2.07" (52.6 mm)
  • Diameter: 1.88" (47.8 mm)
  • Weight: 1.06 oz. (30g) less fitting
 
 
 
 
 
 
Engineered Products Co. | 2940 Airport Blvd. Waterloo, IA 50703 | P: (319) 234-0231 | F: (319) 234-8922 | E: info@filterminder.com