The Sensor continuously monitors vacuum in the air induction system, which tells air filter restriction. As vacuum or air filter restriction increases, the sensor gives a comparable voltage output range of .5 to 4.5 volts full scale. Air filter capacity used and remaining air filter service life can be determined throughout the entire life of the filter. Threaded mounting ports can be supplied with 1/8” pipe thread, 3/8” straight thread, or M-10 metric. The sensor is furnished with flying leads, or can be supplied with a connector.Special mounting and connectors available if annual volume warrants (contact Filter Minder).
Specifications
Measurement Type: Pressure or Vacuum (Gage)
Working Pressure Range: 0 to 40 in H2O (0 to 1.5 psi) ; 0 to 10 kPa (0-100 mb)
Media: Air ; Others compatible with silicon rubber
Burst Pressure: 20 psi
Proof Pressure: 10 psi
Supply Voltage: 5 Vdc ± .25 Vdc
Supply Current: 5 mA MAX
Current Output: 2.2 mA MAX
Output Impedance: 5000 ± 20% ohms
Accuracy: ± 2.5% full scale
Output Voltage: 0.5 - 4.5 Vdc
Over-Voltage Protection: 80 V
Reverse Polarity Protection: 36 V, Misconnect 16 V
Storage Temperature: -40°C to 125°C [-40°F to 257°F]